DSpace DSpace

Biblioteca Digital do IPG >
Escola Superior de Educação, Comunicação e Desporto (ESECD) >
Artigos em Acta de Conferência Internacional (ESECD) >

Utilize este identificador para referenciar este registo: http://hdl.handle.net/10314/3805

Título: Reliability of wearable heart rate measurement in a specific swimming-pool test for bodyboarders.
Autores: Reis, Vitor
Ribeiro, Pedro
Marinho, Daniel
Costa, Aldo
Costa, Mário
Guerra, Afonso
Silva, António
Garrido, Nuno
Data: 2017
Citação: REIS VM, RIBEIRO P, MARINHO DA, COSTA AM, COSTA MJ, GUERRA A, SILVA AJ, GARRIDO ND (2017) Reliability of wearable heart rate measurement in a specific swimming-pool test for bodyboarders. Book of Abstracts from the 8th Asia-Pacific Conference on Exercise and Sports Science and 7th International Conference on Sport and Exercise Science. pp. 63. Bangkok, Thailand.
Resumo: Objectives: A PubMed search has revealed a mere 4 papers published on bodyboard science, from 1995 to date. Moreover, modern wearable technology enabled to accurately assess heart rate during aquatic activities. The aims of the present study were to assess the reliability of a specific swimming-pool test for bodyboarders by measuring: i) aerobic response through heart rate; ii) anaerobic response through post-exercise peak blood lactate; and, iii) performance through mean velocity. Methods: Ten experienced bodyboarders (more than 4 years of training) volunteered for the study. The mean (±SD) age, body mass and height of the subjects were, respectively: 21,3±5,0 years, 64,7±8,6 kg, 1,72±5,9. The subjects performed a specific swimming-pool test. Testing was performed in a 50-m indoor heated swimming pool (26-27˚) and consisted of a 400-m individual time trial. The subjects paddled on a standard bodyboard using bodyboard swim fins. The test was repeated 72-h after. During both tests heart rate was continuously assessed with a Polar® device (RCX5 with H2 sensor). After testing ear-lobe capillary blood lactate was measured every minute until levelling-off with a Accutrend Plus® device. Reliability of repeated measurements was assessed with the coefficient of variation and significance level was set at p≤0.05. Results & Discussion: To the best of our knowledge this was the first study to assess the reliability of heart rate, blood lactate and velocity during a swimming-pool specific test for bodyboarders. Due to weather and tide constraints during natural bodyboarding it is difficult to have a reliable physiological response under field conditions. Hence, we propose herein a swimming-pool specific test based on a surfing specific swimming-pool test. In the present study, coefficients of variation were: 0,3% for peak heart rate, 1,8% for mean heart rate, 14,7% for post-exercise peak blood lactate and 1,7% for mean paddling velocity. Average measures with the two test were: 182,2±13,9 bpm peak heart rate, 170,3±15,4 bpm for mean heart rate, 9,7±2,6 mmol/L for post-exercise peak blood lactate and for 1,27±0,09 m/s mean paddling velocity. Conclusion: We conclude that the 400-m bodyboard paddling specific swimming-pool test seems to be a reliable measure of performance (mean velocity) and aerobic response (heart rate). Anaerobic response during this test (post-exercise peak blood lactate) presented a less reliable profile.
URI: http://hdl.handle.net/10314/3805
Aparece nas Colecções:Artigos em Acta de Conferência Internacional (ESECD)

Ficheiros deste Registo:

Ficheiro Descrição TamanhoFormato
2017 Reis et al - Asia-Pacific Conference.pdf608KbAdobe PDFVer/Abrir
Sugerir este item a um colega